(i)Diameter of stirrups in the connection zone is enlarged from 8 to 10 mm. (ii)The stirrups in the connection zone are welded by sides to a vertical steel plate which is welded to the beam bottom cho
(i) Diameter of stirrups in the connection zone is enlarged from 8 to 10 mm.
(ii) The stirrups in the connection zone are welded by sides to a vertical steel plate which is welded to the beam bottom chord plate, Fig. 5.
(iii) The welding thickness is limited to 0.3/, where / is diameter of the bar to be welded.
The specimens of R-ITC-1 and R-ITC-2 are replications which have the enhanced features defined above. All the improvements are discussed with the skilled engineers acknowledged.
摘要:由于对预制混凝土结构的抗震性能和延性缺乏深入的认识,很难达到地震时所能表现出来的延性要求。其限制主要与梁柱连接作为主要的荷载传递路径有关。研究了两种不同的普通钢筋混凝土梁柱连接。顺便提一句,工业型接头采用干式和湿式安装技术,住宅式接头采用湿连接方式。试件受循环位移的影响。为了获得连接细节的强度、刚度和延性特性的信息,在试验期间更新了连接节点的初步设计。通过对损伤的观测,建立了一套改进的试件,并进行了试验,取得了较好的性能。工业和住宅两种连接方式均表现出稳定的荷载-位移循环,耗能率高达2%,但有明显的收缩和震慑作用,临界截面的比值在3%左右的漂移水平处出现。对试验样品进行了数值模拟,对分析工具进行了标定,并在实验结果和数值结果之间得到了满意的近似结果。
1、介绍
地震多发地区预制结构设计中的主要挑战之一是连接节点的合理设计,主要是梁柱连接的设计。各种类型的梁柱连接,如整体连接,模拟连接,螺栓连接,干钉连接等都在实践中得到了应用。不同类型连接的细节,在设计和行为方面,由Park[1]和fib Bulletin 43[2]广泛讨论。
Bhatt和Kirk[3]和Seckin和Fu[4]开发了一些用于预制混凝土结构的焊接连接,虽然这些连接的性能是可以接受的,但细节需要焊接。梁、柱的加固,可能会在现场引起一些问题。French等人[5,6]测试了各种类型的梁柱连接,其中一些在连接区域外开发了塑料铰链。据透露,螺纹钢筋连接在性能、制造和经济方面,锥形螺纹连接被证明是最有利的解决方案。Ersoa和Tankut[7]在反向循环荷载下试验了干节点预制混凝土梁。最初的梁由两个钢板组成,一个在顶部,另一个在底部,焊接在柱支架和梁上的锚固钢板上。后来,通过增加侧板对设计进行了修改。边板构件的强度、刚度和耗能能力与整体构件相当。然而,适用于这样的细节在现场是相当困难的,需要一个仔细的质量控制机制。Priestley和Tao[8]提出了在地震多发地区采用无粘结预应力的抗侧力体系。Nakaki等人[9]提出了一种预制混凝土延性框架,利用预制混凝土固有的离散性质,在连接中提供延性连接。这些延展性也消除了对短柱的需求,它包含一根棒材,其强度可以很好地确定,从而有效地限制了可以转移到框架中较少延展性部件的载荷。PRASSS项目[10,11]是对预制结构地震反应的试验研究中最值得注意的一项工作。预制混凝土框架系统的延性连接,预制混凝土面板系统的延性连接,无粘结筋的预制框架,高性能纤维增强混凝土能量预制混凝土框架的吸油节点是研究的。
Korkmaz和Tankut[12]测试了6个在反向循环荷载下梁对梁连接组件。将预制构件的性能与整体试件的性能进行了比较。为了提高该节点的抗震性能,对今后的研究和推广提出了几点建议。在本文的上下文中也给出了案例。Ertas等人[13]试验了四种类型的延性抗弯预制混凝土框架连接和一个整体混凝土连接。改进后的螺栓连接在强度、延性和性能方面表现出最佳的性能。